Customization: | Available |
---|---|
Material: | PVC |
Style: | Customized |
Still deciding? Get samples of US$ 0/Square Meter
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Specifications:
Description: | Standard | Unit | Result |
Total thickness | EN 428 | mm | 2.0/2.5/3.0 |
Weight | EN 430 | g / m2 | 2900 |
Width | EN 426 | m | 2.0 |
Length of Sheet | EN 426 | m | 20/15 |
Electric Properties | EN1081 | <1.0*10 6Ω |
Decay time | SJ/T10694-2006(IVI<100V) | Equal 0.3s |
Charge voltage | SJ/T10694-2006(IVI<100V) | Equal 70 |
Fire Rating | DIN4120 | B1 |
Combustion properties | SJ/T11236-2001(<10S) | Equal 0.35s / FV-0 |
Smoke density | ASTME-662 | <450 |
Amount of anti-wear | SJ/T11236-2001(≤0.02g/cm2) | Equal 0.014 |
Anti-bacterial | DIN EN ISO 846-A/C) | Non |
Wheel pressure | EN 425 | no influence |
Toxic testing | GB18586-2001 | Suitable |
Smoke toxicity | GB8024-2006 | ZA3 |
Performance:
Residual stability | EN 433/SJ/T11236-2001 | <0.1mm/≤0.15mm |
Dimensional stability | EN 434 | ≤0.35% |
Colour Fastness | EN ISO 105 - B02 | Degree 6 |
Resistance to Chemicals | DIN423, FN ISO 26987 | Good |
Impact sound absorption | VLI, ISO104, ISO717 | Approx. 2dB |
Slip Resistance | DIN51130/EN13893 | R9/DS |
Thermal Conductivety | EN12667 | 0.03w/(m.k) |
Clean Rooms | ASTM F 51/68 | Class A, non-shedding |
Suitable for use in fllowing classes of clean room: ISO 1466-11999 Class 4 |
Installation:
Karmeen Conductive tile and Static-Dissipative tile should be installed on sub floors that are leveled, smooth and free of cracks. Residual humidity should be under 2.5% tested with the CM Dumb test. Tiles Floor, adhesive and installation site should reach a temperature of at least 18ºC at least 24 hours before installation. and paste the tiles with qualified conductive glue below 105 Ohm. For futher details on installation methods, please ask us.
Maintenance:
Because Karmeen floor is unpermeable, the surface dirty is easy to clean.
Avoid sharp scratches on the floor by hard object, and maintain a smooth surface.
Cleaning the floor by neutral detergent, dry after washing, then coated with anti-static wax.
Serious dirty or spots can be used to clean the floor cleaning machine.
Application:
Widely applied to electronics, microelectronics, telecommunications, network floor, clean room, computer room and other precision instrument and room for equipment operation.